When commercial facilities face rising demand charges and grid instability, the CICS-17 provides 16.78 kWh of intelligent battery storage to cut peak costs by 30-60%. This system features Supro Energy’s advanced thermal management and modular design, enabling flexible deployment for warehouses, manufacturing plants, data centers, and mixed-use developments requiring reliable backup power and demand charge reduction.
Empower IT brings you the CICS-17—combining Supercapacitor hybrid technology with Supro’s innovative liquid cooling systems and intelligent controls for maximum safety, performance, and longevity.
The Supro Energy liquid cooling system utilizes micro-channel enhanced heat transfer technology, delivering superior thermal performance while maintaining industry maturity and strong transferability. This advanced cooling enables 100% liquid contact for superior energy efficiency compared to traditional air cooling, which typically results in PUE values of 1.4 or higher.
Supro Energy 400V-16.78KWH
| Item | Condition | Specification |
| 3.1. Nominal Capacity | Standard Discharge / Charge | 21.0Ah |
| 3.2. Nominal Voltage | 3.70V | |
| 3.3.Standard Charge | Constant current | 21.00A |
| Limited voltage | 4.30V | |
| Charging cut-off current | 1.05A | |
| Temperature | 25°C ± 5°C | |
| 3.4. Standard Discharge | Constant current | 21.00A |
| Discharging cut-off voltage | 2.70V | |
| Temperature | 25°C ± 5°C | |
| 3.5. Max. cont. Charging Current | RT | 42.00A |
| 3.6. Max. cont. Discharging Current | RT | 63.00A |
| 3.7. Max. Peak Charging Current | 10s Charge | 63.00A |
| 3.8. Max. Peak Discharging Current | 10s Discharge | 84.00A |
| 3.9. Internal Resistance | AC, 1kHz | <1.10mΩ |
| 3.10. Weight | 348.0g ± 10.0g | |
| 3.11. Temperature Range | Chargea | 0°C ~ 55°C |
| Discharge | -20°C ~ 55°C | |
| 3.12 Energy Density | Standard charge/ standard discharge | ~ 220Wh/Kg |
| 3.13 cycle life | 1C1D @ @25℃ | ≥20000 |
| a:Reduce the charge current when charger in a low temperature environment . | ||
| Items | Energy type |
| Rated Energy | 42Ah (8.39KWh) @25℃ ±5% |
| Connection | 2P54S (27S2P*2) |
| Nominal Voltage | 199.8V |
| Min Voltage | 151.2V |
| Max Voltage | 226.8V |
| Max Current | 100A |
| Items | Unit | Value | |
| Battery System | Rated Capacity | Ah | 42 @25℃ ±5% |
| Module Per Rack | pcs | 2 | |
| PDU | pcs | 1 | |
| Rack Rated Voltage | V | 399.6 | |
| Rack Minimum Voltage | V | 302.4 | |
| Rack Maximum Voltage | V | 453.6 | |
| Energy Per Rack | KWh | 16.78 | |
| BMS | Battery Management System | pcs | 1 pcs main BMS+ 2 pcs slave BMS |
2.1 BMS parameters
| Working voltage | 9V DC~16V DC | |
| Working environment temperature | -30℃~75℃ | |
| Operating humidity | 5% ~90%, no condensation | |
| Single voltage acquisition | Range of collection | 0V~5V |
| Acquisition accuracy | 0V~2.3V,error:±6mV | |
| 2.3V ~5.0V, accuracy:5thousand | ||
| Acquisition cycle | ≤300ms | |
| Battery temperature measuring | Range of collection | -40℃~+125℃ |
| Acquisition accuracy | -40 C ~-30c, error: ±2℃ | |
| -30℃~+60℃,error:±1.5℃ | ||
| +60℃~+85℃,error:±2℃ | ||
| +85℃~+125℃,error:±4℃ | ||
| Acquisition cycle | ≤300ms | |
| Air duct inlet and outlet temperature acquisition | Range of collection | -40℃~+110℃ |
| Acquisition accuracy | -30℃~+85℃,error:±1.5℃ | |
| -40℃~-30℃,error:±2℃ | ||
| +85℃~+110℃,error:±4℃ | ||
| Acquisition cycle | ≤1s | |
| Air duct inlet and outlet temperature acquisition | Range of collection | ±350A |
| Acquisition accuracy | 0A ≤ Current absolute80A, error : ±0.4A | |
| 80A < Current absolute value ≤200A, accuracy:5thousand | ||
High voltage collection
| Range of collection | 0V~500V |
| Acquisition accuracy | 5‰ | |
| Insulation resistance sampling | Insulation alarm error | Secondary alarm point:200K±30Kω |
| Level alarm:500K±100Kω | ||
| Insulation alarm | 0 Insulation resistance ≤ ≤170K: two-level alarm | |
| 0 Insulation resistance ≤ ≤170K: two-level alarm | ||
| 230K < Insulation resistance ≤400K: level alarm | ||
| 400K < Insulation resistance ≤600K: level alarm or no alarm | ||
| 600K < Insulation resistance: no alarm | ||
| Acquisition accuracy | ≤12s | |
| Balance | Opening conditions | Slow filling process: The highest unit voltage >4.05V; Single pressure >50mV ( online calibration)
|
| Balance current | >80mA | |
| SOC Estimating | Estimation errors | ≤5% |
| External drive | Drive mode | High and low level |
| Drive voltage | 12V DC | |
| Driving ability | 3A | |
| External interfaces | CAN Baud rate | 250kbps /500kbps |